The unit accepts inputs from up to 2 partitions giving a total of 3 individual rooms or combinations thereof. With local control panels located in each of the rooms and with both partitions closed, each of the control panels will control their respective rooms. Opening the partition between rooms 1 and 2 will allow the scenes in both rooms to be selected from either of the control panels. This follows for the other room combinations. Initial configuration is achieved using the RASOFT programming software. ??
The RAIPC is designed for applications where a room is to be divisible into smaller rooms. The unit has 2 volt free switched inputs indicating the status of the partitions. Depending on the installation and customer preference, the switch inputs can come from a variety of devices from manually operated key-switches to proximity switches located on the partitions. The RAIPC unit requires the use of th e RAPSU external power supply. Or other 12V d.c. power supplies conforming to SELV requirements. Connect the power supply and the volt free switch inputs as shown in Fig. 3 below. The RAIPC is supplied complete with 2 external aerials. For best performance these should be fixed at an angle of 90 degrees or greater to each other. ?